Description
Oxidized bitumen is blown from blowing hot air to pure bitumen at the final stage of the purification operation in this process, hot air with a temperature of 200 to 300 degrees Celsius is blown through a perforated tube into a compartment containing bitumen.
Oxidized bitumen is categorized based on softening points and penetration rate. For example, oxidized bitumen 85/40 is a type of bitumen whose softening point is 85±5 degrees Centigrade and its penetration rate is 40±5 (0.1mm). Oxidized bitumen is also expected to make up for weight loss under heat. The softening point in oxidized bitumen is much higher than in regular bitumen, causing lower thermal sensitivity.
Various pickings are available for customer’s purposes and conveniences:
- Kraft bag
- Meltable plastic bag
- Drum
- Bulk
This process gives the Oxidized Bitumen more rubbery properties than its original formula and they are simply harder bitumen.
- Oxidized bitumen is used for the repair and sealing of joints or cracks.
- Oxidized bitumen is used as an adhesive to be used in thermal insulation.
- Oxidized bitumen is used in various industries like roofing, isolation, insulation flooring, mastics, pipe coatings, and electrical applications.
Oxidized Bitumen Products:
Oxidized Bitumen 85/25
|
BINDER PROPERTIES |
REQUIREMENTS |
TEST METHOD |
|
MIN |
MAX |
|
Density@25°C |
1.05 approx. |
ASTM D70 |
|
penetration @25°C |
20 |
30 |
ASTM D5 |
|
Softening point, °C |
80 |
90 |
ASTM D36 |
|
Flash point, °C |
250 |
- |
ASTM D92 |
|
Solubility in trichloroethylene, % |
99.0 |
- |
ASTM D2042 |
|
Spot test, xylene |
Negative |
AASHTO
T102 |
|
Test on residue After TFOT |
|
Change of
Mass WT% |
- |
0.2 |
ASTM D6 |
Oxidized Bitumen 90/15
|
BINDER PROPERTIES |
REQUIREMENTS |
TEST METHOD |
|
MIN |
MAX |
|
Density@25°C |
1.05 approx. |
ASTM D70 |
|
penetration @25°C |
10 |
20 |
ASTM D5 |
|
Softening point, °C |
85 |
95 |
ASTM D36 |
|
Flash point, °C |
250 |
- |
ASTM D92 |
|
Solubility in trichloroethylene, % |
99.0 |
- |
ASTM D2042 |
|
Spot test, xylene |
Negative |
AASHTO
T102 |
|
Test on residue After TFOT |
|
Change of
Mass WT% |
- |
0.2 |
ASTM D6 |
Oxidized Bitumen 95/15
|
BINDER PROPERTIES |
REQUIREMENTS |
TEST METHOD |
|
MIN |
MAX |
|
Density@25°C |
1.05 approx. |
ASTM D70 |
|
penetration @25°C |
10 |
20 |
ASTM D5 |
|
Softening point, °C |
90 |
100 |
ASTM D36 |
|
Ductility
@ 25°C |
1.5 |
- |
ASTM D113 |
|
Flash point, °C |
250 |
- |
ASTM D92 |
|
Solubility in trichloroethylene, % |
99.0 |
- |
ASTM D2042 |
|
Spot test, xylene |
Negative |
AASHTO
T102 |
|
Test on residue After TFOT |
|
Change of
Mass WT% |
- |
0.2 |
ASTM D6 |
Oxidized Bitumen 95/25
|
BINDER PROPERTIES |
REQUIREMENTS |
TEST METHOD |
|
MIN |
MAX |
|
Density@25°C |
1.05 approx. |
ASTM D70 |
|
penetration @25°C |
20 |
30 |
ASTM D5 |
|
Softening point, °C |
90 |
100 |
ASTM D36 |
|
Flash point, °C |
250 |
- |
ASTM D92 |
|
Solubility in trichloroethylene, % |
99.0 |
- |
ASTM D2042 |
|
Spot test, xylene |
Negative |
AASHTO
T102 |
|
Test on residue After TFOT |
|
Change of
Mass WT% |
- |
0.2 |
ASTM D6 |
Oxidized Bitumen 115/15
|
BINDER PROPERTIES |
REQUIREMENTS |
TEST METHOD |
|
MIN |
MAX |
|
Density@25°C |
1.05 approx. |
ASTM D70 |
|
penetration @25°C |
10 |
20 |
ASTM D5 |
|
Softening point, °C |
110 |
120 |
ASTM D36 |
|
Ductility
@ 25°C |
1.5 |
- |
ASTM D113 |
|
Flash point, °C |
250 |
- |
ASTM D92 |
|
Solubility in trichloroethylene, % |
99.0 |
- |
ASTM D2042 |
|
Spot test, xylene |
Negative |
AASHTO
T102 |
|
Test on residue After TFOT |
|
Change of
Mass WT% |
- |
0.2 |
ASTM D6 |
Oxidized Bitumen 125/10
|
BINDER PROPERTIES |
REQUIREMENTS |
TEST METHOD |
|
MIN |
MAX |
|
Density@25°C |
1.05 approx. |
ASTM D70 |
|
penetration @25°C |
7 |
12 |
ASTM D5 |
|
Softening point, °C |
120 |
130 |
ASTM D36 |
|
Flash point, °C |
250 |
- |
ASTM D92 |
|
Solubility in trichloroethylene, % |
99.0 |
- |
ASTM D2042 |
|
Spot test, xylene |
Negative |
AASHTO
T102 |
|
Test on residue After TFOT |
|
Change of
Mass WT% |
- |
0.2 |
ASTM D6 |